DEW POINT ANALYSER DP-200
HNL markets a full range of Hygrometers using state-of-the-art electronics to the standards & Specifications of MOISTURE SENSORS. They incorporate the most accepted & highly reliable, accurate, fast, stable and long life SENSORS having unique AUTOMATIC calibration feature and are equipped with single or dual alarms, adjustable over the complete range. They are ideal for rapid check or continuous online analysis of dew point or moisture content of air or gas in dryers or industrial processes.
- Direct digital indication – no charts or graphs
- Portable & continuous online
- Accurate to 1 ppm moisture
- Overall range – 110°c to 20°c
- For high-pressure vacuum, general & hazardous area applications
- With unique automatic calibration feature requires nothing but
- Room air for calibration
Description
The most important feature of the Sensors system is the automatic calibration facility. Each sensor is precisely manufactured so as to saturate with water vapor at its design maximum. Hence when the sensor is exposed to moisture above its maximum operating range, it will rapidly come into equilibrium at its design maximum and cease to respond to any further moisture. This forms the basis of automatic calibration.
The Sensor can be calibrated by simply exposing the sensor to an atmosphere which is “wetter” than the operating range of the sensor (Room Air is sufficient) and adjusting the Calibration control on the front panel of the instrument to display the maximum range. The sensor is Recalibrated and ready to use.
Re-calibrations can be carried out in-situ and without taking recourse to any special equipment or skilled personnel. The net result is reduced downtime. Minimum Calibration costs & immediate verification of the system.
Specification
Sensor | High capacitance aluminum oxide, intrinsically safe certified |
---|---|
Sensor Guard | Sintered bronze |
Sensor Mounting | 14 x 12.5 mm STD. Auto thread |
Sensor Active Length | 76.2 mm |
Sensor Overall Length | 143 m |
Electrical Connection | Standard TV socket |
Minimum Resolution | 0.1°C for Dew point |
(Digital Display) | 01 PPM for moisture |
Flow Rate to Sensor | 2 to 5 LPM (Optimum) |
Maximum Operating Pressure | 340 bar |
Warm Up. | < 60 Seconds |
Operating Temperature | 0 to 50 °C |
Repeatability | 0.3 °C Dew point |
Automatic Calibration | Potentiometric adjustment on front of panel |
Typical Response Time | Wet to Dry – (23000 to 100 PPM) : < 40 seconds Dry to Wet – (100 to 23000 PPM) : <10 seconds |
Display | 3 1/2 Digit LED/LCD or 4” Precision Analogue Meter |
Power | 240 V or 110 V AC or 12 V Dry Cells or Rechargeable Batteries with charger |
Alarms | One (wet) adjustable over range Two (wet & dry) adjustable over range |
Housing | IP 65 |