AMBIENT AIR QUALITY STATION AQ-200

  • AMBIENT AIR QUALITY STATION AQ-200


    Air Quality stations deliver precise measurement data in real-time for a wide range of air pollutants in a discreet and compact package. Measureable parameters include: ozone (O3); nitrogen dioxide (NO2); nitrogen oxides (NOx): carbon monoxide (CO); carbon dioxide (CO2); sulphur dioxide (SO2); volalite organic compounds (VOC); and particulate matter by mass (PM10 and PM2.5) or size distribution (0.3 to 10 µm, 8-channels)

    • Multiple gas measurements
    • Real-time data acquisition
    • Multi -point factory calibration
    • Zero and Span calibration user facility
    • PC software included
    • Temperature and humidity sensors
    • Remote site operation
    • Particle monitoring PM2.5 PM10, TSP*
    • Pole or wall installation
    • Wind speed and direction sensors*
    • Compact and low weight

Description

HNL’s AQ-200 affords high performance within a flexible and cost-effective package. Sensors can be integrated that measure temperature, humidity, wind speed, wind direction, environmental noise, solar radiation and other meteorological parameters. Data is stored on an SD card and remotely accesible in real-time via GSM modem, low power radio, Ethernet or other communications.

The AQ-200 Air Quality Station meets the global trend towards real-time measurement of air quality in the micro-environment. This is driven by the need to answer important questions in localized areas of human habitation using newer, smaller, lower cost, intelligent measurement technology linked by inexpensive network communication systems.

Specification

Display A) H2S
B) NO
C) NO2
D) O3
E) CO
F) SO2
0 – 25 PPM (0-15000 microgram/m3)
0 – 20 PPM (0-15000 microgram/m3)
0 – 20 PPM (0-25000 microgram/m3)
0 – 02 PPM (0-3000 microgram/m3)
0 – 50 PPM (0-15000 microgram/m3)
0 – 20 PPM (0-30000 microgram/m3)
Resolution 3 PPB
Particulate Monitor Module

Range
Lowest Detection
Accuracy
Precision
Sharp Cut Points
Power

Forward light scatter nephelometer

0-6000 µg/m3
0.01 µg/m3
8% NIOSH 0600
3µg/m3
PM1/PM2.5/PM10
5.2W

Temperature & Humidity Module

Temperature
Humidity
Accuracy@25 °C
Resolution T
Resolution RH
Power

-20 °C to +100 °C
0-100% RH
+/-0.3 °C / +/-2% RH
0.01 °C
0.1% RH
0.05 W
Control Module

Data Storage
Sampling Rate
Communication
Display
Diagnostic
Power

1 GB
2-255 min
RS 232
4×20
Yes
5.8W
Environmental Operating Range -20 °C to 50 °C 10 to 90% RH (non condensing)
Power Requirements 24 V DC (power subject to configuration) AC power module 100 – 250 V AC
Standard Enclosure Fibre reinforced polyarbonate / IP66 NEM A4 Thermal insulation in internal walls
Weight 15-25 Kg (subject to configuration)
Other Sensor Options Noise Sensors / Particulate counters Meteorological sensors
Enclosure Options Mounting accessories Metal enclosures

Note : Specifications and Features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. Due to hnl’s commitment to research, design and product improvement, specifications are subject to change without notice.